Materials Thermal Analysis

Differential Scanning Calorimeters (DSC)

Reliable, Cost-Effective Calorimetry

  • Multiple heat flow sensor options: base, high-sensitivity, corrosion-resistant, and energetic sample-compatible.
  • Flexible cooling systems: water, mechanical, or liquid nitrogen (LN2).
  • Surrounding dual-PID temperature control delivers accurate thermal curves during both heating and cooling.
  • Ultra-light mineral furnace design reduces heat loss and enhances thermal uniformity and energy efficiency.
  • Optional high-pressure DSC model supports measurements up to 1000 psi for advanced material studies.

DSC Specification

Specification

Capability

Temperature Range

-150~600°C

Temperature Accuracy

±0.1°C

Temperature Precision

±0.01°C

Program Rate

0.1~200°C/min

Calorimetric Accuracy

±0.1%

Noise

0.5 μw

Thermal Gravimetric Analyzers (TGA)

Precise Mass Loss and Decomposition Analysis

  • Proprietary, self-developed hang-down microbalance with 0.1 μg resolution and high stabilityno buoyancy correction required.
  • Temperature range options: ambient to 1000°C / 1200°C / 1500°C.
  • Insulated balance housing minimizes thermal drift and ensures accurate mass measurements.
  • Combines high sensitivity, low drift design, and robust thermal insulation for exceptional long-term precision.
  • Seamlessly integrates with mass spectrometry (MS) or FTIR for evolved gas analysis (EGA) in real time.

TGA Specification

Specification

TGA 1000

TGA 1200

TGA 1500

Temperature Range

Room temp-1000°C

Room temp-1200°C

Roomtemp-1500°C

Temperature Accuracy

±0.5°C

Description

±0.1°C

Temperature Precision

±0.1°C

Description

±0.01°C

Program Rate

0.1-300°C/min

0.1~60°C/min

0.1~60°C/min

Resolution

0.1 μg

Description

±0.1%

Measuring Range

±200 mg

Description

0.5 μw

Dynamic Baseline Drift

25 μg (No blank background subtraction)

Description

Description

Repeatability

10 μg

Description

Description

Simultaneous Thermal Analyzer (STA)

Precise Mass Loss and Decomposition Analysis

  • Simultaneous measurement of TGA and DSC (DTA) for comprehensive thermal analysis.
  • Optimized for evolved gas analysis with high-resolution detection of micro-scale mass and heat changes.
  • Proprietary hang-down balance with thermal insulation and low driftaccuracy without buoyancy correction.
  • Micro furnace design significantly reduces gas buoyancy and enhances baseline stability.

STA Specification

Specification

STA 650

STA 1200

STA 1500

Temperature Range

-40°C-650°C

Ambient to 1200°C

Ambient to 1500°C

Program Rate

0.1-100 °C/min

0.1-40 °C/min

0.1-40 °C/min

DSC Sensitivity

<1 μW

<4 μW

<4 μW

TGA Range

400 mg

Description

0.5 μw

TGA Readability

0.1 μg

Description

Description

Thermocouple

Type K

Type R